• Our company takes the energy management of the structures from the human control within the System solutions unit and transforms it into an occupancy oriented and fully manageable platform with sensor control.
  • Our most important privilege is a system design that shows the consumption according to the usage which can save the connected systems in a way that will provide the most savings and strictly according to the needs rather than the technical personnel initiative and can save in the most ergonomic way.
  • This system comes to life with our occupancy-oriented management system which is mostly used in buildings instead of Energy saver. Because the Enery saver is a design that is very open to abuse.
  • Our logic and company policy is an occupancy-oriented management system, but with high engineering knowledge and international comfort and the ability to create a system that can fully save according to the standards of chain groups.
  • In this context, our systems can communicate with each other, can be managed remotely, maintenance, repair and malfunction interventions can be built remotely to serve in an integrity.

Basic model

Components;

    • Motion sensor
    • Door sensor
    • Window sensor
    • Control Card (3 outputs featured) • Lighting• Socket• Air Conditioning
    • It is the model that is applied for short-term use which is designed in a timed manner and works with the logic of motion sensor in lighting equipment and air conditioning elements in all devices where air conditioning is made. For example, air conditioning or lighting elements are able to manage with adjustments such as 30 min-60 min.

Basic plus model

Components;

  • Motion sensor
  • Door sensor
  • Window sensor
  • Control Card(3 outputs featured, 1 data) • Lighting• Socket• Air Conditioning• DATA
  • It is the model applied in short time use which is designed in a timed manner and works with the logic of motion sensor in lighting equipments and elements in all devices where the air conditioning is made. For example, it manages the air conditioner or lighting elements with adjustments such as 30 min-60 min. It can communicate with the BMS system.

Standart model

Components;

    • Occupancy sensor
    • Door sensor
    • Window sensor
    • Control card (8 outputs featured) • Lighting• Socket • Air Conditioning• Secondary contact• Other space equipments will be 4 portas.
    • After receiving a contact from the door, the scan is started. After an occupancyis detected, the air conditioner continues to operate at the desired performance until the door contact is activated again. If the window is opened, the air conditioning automatically switches off. The system that works until the door is opened supports 2 or more people in the room.

Standart plus model

Components;

    • Occupancy sensor
    • Door sensor
    • Window sensor
    • Control Card (8 outputs featured,1 data) • Lighting• Socket• Air Conditioning• Secondary contact •Other space equipments will be 4 ports • DATA
    • After receiving a contact from the door, the scan is started. After an occupancy is detected, the air conditioner continues to operate at the desired performance until the door contact is activated again. If the window is opened, the air conditioning automatically switches off. The system that works until the door is opened supports 2 or more people in the room. It provides BMS supported operation.

Professional Model

Components;

  • Occupancy Sensor
  • Door sensor
  • Window sensor
  • Control Card (16 outputs featured) • Lighting• Socket• Air Conditioning• Secondary contact• Speed contact control • Valve control• Curtain control• Lighting scenario control• Other space equipments
  • After receiving a contact from the door, the scan is started. After an Occupancy is detected, the air conditioner continues to operate at the desired performance until the door contact is activated again. If the window is opened, the air conditioning automatically switches off. The system that works until the door is opened supports 2 or more people in the room.
  • The difference from the other products is that it gives the information of how many people are in the room to the required center and it is a system that has the principle of counting people completely.

Thermostat

  • Digital Display
  • Manual temperature and fan speed control

Visual person counting

The number of people in the areas such as lobbies, ballrooms, sports halls, meeting rooms are determined and constructed according to this number with artificial intelligence system that is automatically air-conditioned. PC-based service.

Ultrasonic corridor sensor

It will provide sensor lighting management with human detection method. Available in 2, 3, 4 contact versions.